Almost every orthodontic patient is X-rayed at least once, and many have more than one set of images over a course of treatment. Each of those images is a medical exposure to ionising radiation, and each is governed by the Ionising Radiation (Medical Exposure) Regulations 2017, known as IR(ME)R. This guide explains IR(ME)R for orthodontic practices in plain English: who the four duty holders are, what the employer must have in writing, how to justify and optimise an orthodontic radiograph, what counts as an accidental or unintended exposure, and what an inspector is likely to ask to see. It is written for practice owners, orthodontists, practice managers and the nurses and radiographers who press the button. Key takeaway IR(ME)R puts legal duties on four roles: the employer, the referrer, the IR(ME)R practitioner and the operator. The employer must have written procedures and protocols, a quality assurance programme, an equipment inventory, training records and an incident process. The practitioner must justify and authorise each exposure, and the operator must keep the dose as low as reasonably practicable. If any of those roles is vague in your practice, that is the first thing to fix. IR(ME)R is the set of regulations that protects patients from unnecessary or excessive medical radiation, and it applies to dental X-rays in both NHS and private practice. The Care Quality Commission explains that the regulations set out the responsibilities of the employer, referrer, IR(ME)R practitioner and operator, and that they cover minimising unintended, excessive or incorrect exposures, justifying each exposure so that the benefit outweighs the risk, and optimising diagnostic doses to keep them as low as reasonably practicable. CQC enforces IR(ME)R in England and states that it applies to the independent sector and the public sector alike. Wales, Scotland and Northern Ireland have their own enforcing authorities, so check who inspects you if you work outside England. 4 duty holders named in IR(ME)R: employer, referrer, practitioner and operator 2017 year the current regulations were made (SI 2017/1322), in force from 6 February 2018 2024 amendments took effect on 1 October 2024, including changes to regulation 8 on recording incident analyses The regulations sit alongside a separate set of rules, the Ionising Radiations Regulations 2017 (IRR17), which protect staff and members of the public and are enforced by the Health and Safety Executive. The simplest way to remember the split is that IR(ME)R protects the person in the chair, and IRR17 protects everyone else in the building. A compliant practice needs both, and a radiation protection adviser can help you with the IRR17 side. This article concentrates on IR(ME)R because it is the regime that governs the decision to take an image in the first place. If you want the patient-facing version of this topic, our guide to orthodontic X-ray radiation answers the questions families ask, and it is worth giving to patients who ask why the practice wants a scan. The four duty holders are the employer, the referrer, the IR(ME)R practitioner and the operator, and in a busy orthodontic practice one person often holds more than one role. What matters is that each role is defined in writing, that the person holding it is entitled to act in it, and that they have been adequately trained for it. Regulation 10 sets out their responsibilities, and regulation 17 requires that practitioners and operators are adequately trained before they carry out any exposure or practical aspect of one. A frequent weakness is that the employer role is invisible. The practice owner signs the cheques but has never read the procedures that carry their name. If you recognise that, set aside an hour with the owner and walk through the schedule of employer's procedures, because the legal duty to have them in place sits with the employer, not with the clinician. The same governance thinking features in our guide to a CQC inspection of a dental practice. The employer must have written procedures covering the matters in Schedule 2 of the regulations, written protocols for each standard radiological practice, referral guidelines, quality assurance programmes and a system for recording and learning from incidents. Regulation 6 states that the employer must also take steps to ensure the referrer, practitioner and operator comply with those procedures, and that practitioners and operators keep up continuing education and training after qualification, including training on new techniques. The regulations also require the employer to appoint a suitable medical physics expert and involve them in the way the regulations describe. For a dental practice that is normally arranged through the same external provider that carries out your equipment testing, and the expert is involved as appropriate in advising on optimisation, dosimetry and quality control. Put the arrangement in writing and keep the latest report where you can find it. Important A set of procedures downloaded from a template and never read is not compliance. Inspectors test whether the people named in your procedures can describe what they do, so run a short briefing for the team whenever the document changes, and record who attended. An exposure may only go ahead if the practitioner has justified it as showing a sufficient net benefit and has authorised it. Regulation 11 lists what the practitioner must weigh: the specific objectives of the exposure and the characteristics of the individual, the total potential diagnostic benefit, the individual detriment the exposure may cause, and the efficacy, benefits and risk of alternative techniques that involve no or less ionising radiation. Justification is therefore a decision about this patient on this day, not a blanket rule that every new patient has a panoramic image. Consider three patients seen on the same day. A twelve-year-old has a retained primary canine and a suspected ectopic permanent canine, so a radiograph that locates the tooth can change the treatment plan. A thirty-four-year-old with mild lower crowding and a recent panoramic image from her general dentist may not need a new one; the right step is to request the existing image and check that it is of adequate quality. A fifteen-year-old half way through treatment has a bracket that keeps failing, and no image is needed to rebond it. In each case the question is the same, namely whether the result of the image will change what you do. Usually justified Hard to justify The British Orthodontic Society publishes orthodontic radiograph guidelines, now in a fourth edition, and the BOS advice sheets page lists them alongside its guidance on records, consent and medical emergencies. Your employer's referral guidelines should say which guidance you follow, so that the referrer, practitioner and operator are all working to the same document. Regulation 10 requires the referrer to supply enough medical data for the practitioner to judge the net benefit. In practice that means a short, structured entry on the clinical record: the clinical question, relevant history, whether a previous image exists, and the practitioner's justification and authorisation. A single line such as "OPG to locate upper left canine, no previous imaging, justified and authorised by [name]" is far more useful to an inspector than an unexplained image in the file. Digital pathways make this easier because the history is already attached to the patient record. Virtual Consultant Online's online assessment captures the patient's goals, concerns and photographs before the first appointment, so the clinician arrives with context rather than starting from a blank page. Our guides on CBCT versus OPG X-rays and the cephalometric X-ray explain what each image is for, which is the starting point for justifying one. For an individual of childbearing potential, the person carrying out the exposure must have enquired whether they are pregnant or breastfeeding, if relevant. This is a condition of regulation 11(1)(f), and your written procedures should say who asks, how the answer is recorded and what happens if the answer changes the justification. Teenage patients are the group most likely to be overlooked, because the enquiry feels awkward with a parent in the room. Build a script that works with a young person, offer a private moment where appropriate, and record the outcome. The NHS page on X-rays is a useful plain-language reference to share with families. Keep the context with the patient record Assessment answers, photographs and the quote live on one record in Virtual Consultant Online, so the referrer and practitioner start from the same information. See the patient journey from the patient's side. Try the online quote → Optimisation means the practitioner and the operator keep every dose as low as reasonably practicable while still producing an image that answers the clinical question. Regulation 12 makes the operator responsible for selecting equipment and methods that achieve this, with regard to quality control, assessment and evaluation of patient dose, and adherence to any diagnostic reference levels the employer has established. A poor image is a double failure: the patient has been exposed and the answer is still missing. Practical habits that support optimisation Equipment is part of optimisation. Regulation 15 requires the employer to implement a quality assurance programme for equipment, to undertake testing before first use and performance testing at appropriate intervals, and to keep the inventory described above. Put the next test date in the practice diary so it is never discovered at an inspection. Our article on GDC CPD requirements for the orthodontic team covers the radiography and radiation protection learning that registrants are expected to keep up to date. An accidental or unintended exposure is one where a patient receives something other than the exposure that was justified and authorised, such as the wrong patient, the wrong examination or a significantly higher dose than intended. Regulation 8 requires the employer's procedures to provide that the referrer, the practitioner and the patient or their representative are informed of a clinically significant unintended or accidental exposure and the outcome of its analysis. It also requires a system for recording analyses of events and potential events, and for taking appropriate action on them. Where the employer knows or has reason to believe that a person was or could have been exposed to levels significantly greater than those generally considered proportionate in the circumstances, the regulations set a clear sequence. The employer must make an immediate preliminary investigation, notify the relevant enforcing authority immediately unless that investigation shows beyond reasonable doubt that no such exposure occurred, arrange a detailed investigation and dose assessment, and report the outcome and corrective measures within the time the enforcing authority specifies. In England the CQC publishes criteria for notification and guidance on keeping records of investigations. The regulations value near misses because they reveal weak points before a patient is harmed. A practice that never records any is not necessarily safe; it may simply not be looking. Review the log at team meetings and keep brief minutes of what changed as a result. Practitioners and operators must not carry out an exposure, or any practical aspect of one, without being adequately trained, and the employer must keep an up-to-date record of that training that the enforcing authority can inspect. The record must show the dates on which qualifying training was completed and the nature of the training. Trainees can take part in practical aspects under the supervision of a person who is adequately trained, which is how a new dental nurse learns, but the supervision should be written down. A sensible IR(ME)R file for the practice Clinical audit is a legal requirement under regulation 7, and simple audits that repeat annually are usually enough for a small practice. The aim is to show that you measured something, compared it with your own standard and changed what you do. Start with measures that are easy to extract from the clinical record. Re-audit after you have made changes. A cycle that stops at the first measurement does not demonstrate improvement, and improvement is what clinical audit is for. Inspectors tend to follow the paper trail from a single patient. They may pick an image, ask who referred it, who justified it, who took it and how you know that person was trained, then ask to see the procedure that covers it, the last equipment test and the incident log. If those answers connect, the rest of the file is credible. Patients and parents ask simpler questions: why do I need this, how much radiation is it, and can it wait? A short, honest answer builds trust and supports informed consent. You do not need to quote dose figures from memory. Explain what the image will show, why it will change your plan and that you keep doses as low as practicable. If you want help writing patient information, the structure in our article on the {a('/blog/orthodontic-patient-consent-process', 'orthodontic patient consent process')} works well for radiography as well as treatment. What good looks like Common gaps None of these is expensive to fix. Most take a morning of focused attention and the discipline to write things down. The payoff is a practice that can explain every image it takes, which protects patients first and the business second. Build the whole patient record in one place Virtual Consultant Online gives orthodontic practices a single record for assessments, photographs, quotes and communications, so everyone involved in a patient's care works from the same information. See how it looks from the patient's side.What is IR(ME)R and who enforces it in orthodontics?
Who are the four IR(ME)R duty holders in an orthodontic practice?
Duty holder Who this usually is What the regulations require of them Employer The legal entity that owns or runs the practice, such as the company or partnership Written procedures and protocols, referral guidelines, quality assurance programmes, equipment inventory and testing, training records, clinical audit and an incident process Referrer The orthodontist or dentist who asks for the image Supply the practitioner with enough medical data to decide whether the exposure has a sufficient net benefit IR(ME)R practitioner A registered dental professional entitled in the employer's procedures to justify exposures, often the treating orthodontist Justify each individual exposure and authorise it, and keep doses as low as reasonably practicable Operator Anyone who carries out a practical aspect, from positioning the patient to pressing the exposure button, such as a trained dental nurse Comply with the employer's procedures, select equipment and technique to keep the dose as low as reasonably practicable, and authorise only where the employer's procedures allow it What must the employer have in place for dental radiography?
How do you justify an orthodontic radiograph?
What does justification look like in a real consultation?
How should the referrer and practitioner record the decision?
What about pregnancy and breastfeeding?
How do you optimise radiation doses in an orthodontic practice?
What is an accidental or unintended exposure, and what must you do?
Event First response Record and learn Wrong patient imaged because two records with similar names were open Stop, inform the practitioner, carry out the preliminary investigation and decide whether notification criteria are met Record the analysis, correct the identification check in the procedure and brief the team Repeated retakes on a unit that appears to be giving over-exposed images Take the unit out of use, inform the practitioner and arrange an equipment check Record doses where available, the fault found and the test date after repair Image taken before the pregnancy enquiry was recorded Inform the practitioner and discuss with the patient, with the outcome recorded Add a hard stop to the pre-exposure checklist Near miss: wrong examination selected on the unit but caught before exposure Correct and continue, and report internally Log it as a potential event under the analysis system and look for patterns What training and records does IR(ME)R expect?
What clinical audits can an orthodontic practice run?
Audit Standard to set How to run it Justification recorded Every image has a recorded clinical question, justification and authorisation Review a random sample of recent records and count compliant entries Retake rate A target set by the practice for rejected images, reviewed by operator and unit Use the log of rejected images and compare each period with the last Image quality Images judged diagnostically acceptable against criteria in your protocol Two clinicians grade a sample and discuss disagreements Pregnancy and breastfeeding enquiry Recorded before every exposure for patients of childbearing potential, where relevant Sample records for the enquiry and the outcome Repeat imaging A documented reason for each repeat image within a treatment course List repeat images and check for justification against your referral guidelines What do inspectors and patients actually ask about radiography?
Six mistakes that put orthodontic practices at risk
IR(ME)R for Orthodontic Practices: Who Is Responsible for Every X-Ray You Take
Published · 18 min read · by Virtual Consultant Online
Citation and AI access
Canonical URL: https://staging.virtualconsultant.online/blog/irmer-radiography-compliance-orthodontic-practice
Citation metadata: /citation.json?url=https%3A%2F%2Fstaging.virtualconsultant.online%2Fblog%2Firmer-radiography-compliance-orthodontic-practice
References
The full text of SI 2017/1322, including regulations 6 to 17 on employer duties, justification, optimisation, accidental exposures and training, and Schedule 2 employer's procedures.
Legislation.gov.uk: The Ionising Radiation (Medical Exposure) Regulations 2017CQC guidance for providers in England on IR(ME)R duties, notifying significant accidental or unintended exposures and keeping records of investigations.
Care Quality Commission: Ionising Radiation (Medical Exposure) Regulations (IR(ME)R)BOS list of clinical and professional guidelines, including the Orthodontic Radiographs Guidelines (4th edition), medical emergencies, records and consent.
British Orthodontic Society: Advice sheets and guidelinesHSE guidance on the Ionising Radiations Regulations 2017, which protect staff and members of the public in work with ionising radiation.
Health and Safety Executive: Ionising radiationThe full text of SI 2017/1322, including regulations 6 to 17 on employer duties, justification, optimisation, accidental exposures and training, and Schedule 2 employer's procedures.
Legislation.gov.uk: The Ionising Radiation (Medical Exposure) Regulations 2017CQC guidance for providers in England on IR(ME)R duties, notifying significant accidental or unintended exposures and keeping records of investigations.
Care Quality Commission: Ionising Radiation (Medical Exposure) Regulations (IR(ME)R)BOS list of clinical and professional guidelines, including the Orthodontic Radiographs Guidelines (4th edition), medical emergencies, records and consent.
British Orthodontic Society: Advice sheets and guidelinesHSE guidance on the Ionising Radiations Regulations 2017, which protect staff and members of the public in work with ionising radiation.
Health and Safety Executive: Ionising radiation